| Pump
Family |
RX PUMPS |
RX |
RX |
RX |
RX |
| Model
No. |
|
160 |
250 |
360 |
500 |
| |
Units |
|
|
|
|
| Parameter |
STANDARD |
|
|
|
|
| Capacity Rated RPM |
GPM (gallons/min) |
92.5 |
133.4 |
198.1 |
268.1 |
| Continuous Pressure Rating |
psi
(lbs/inch2) |
5,080 |
5,080 |
5,080 |
5,080 |
| Admissable Working Pressure @ 50% Flow |
psi
(lbs/inch2) |
6,530 |
6,530 |
6,530 |
6,530 |
| Max Pressure Rating per DIN 24312 |
psi
(lbs/inch2) |
7,250 |
7,250 |
7,250 |
7,250 |
| Inlet Pressure @ Low Pressure Connection |
psi
(lbs/inch2) |
15 - 580 |
15 - 580 |
15 - 580 |
15 - 580 |
| Inlet Pressure @ High Pressure Connection |
psi
(lbs/inch2) |
30 - 6,520 |
30 - 6,520 |
30 - 6,520 |
30 - 6,520 |
| Weight |
pounds (lbs) |
1,499 |
2,050 |
3,417 |
4,740 |
| Displacement / Revolution |
gallons
/revolution |
0.092 |
0.133 |
0.198 |
0.268 |
| Rated
Speed |
RPM
(revolution /min) |
1,000 |
1,000 |
1,000 |
1,000 |
| Max
Speed |
RPM
(revolution /min) |
1,800 |
1,600 |
1,400 |
1,200 |
| |
METRIC |
|
|
|
|
| Capacity
Rated RPM |
litre/min |
350 |
505 |
750 |
1015 |
| Continuous
Pressure Rating |
bar |
350 |
350 |
350 |
350 |
| Admissable
Working Pressure @ 50% Flow |
bar |
450 |
450 |
450 |
450 |
| Max
Pressure Rating per DIN 24312 |
bar |
500 |
500 |
500 |
500 |
| Inlet
Pressure @ Low Pressure Connection |
bar |
1 - 40 |
1 - 40 |
1 - 40 |
1 - 40 |
| Inlet
Pressure @ High Pressure Connection |
bar |
2 - 450 |
2 - 450 |
2 - 450 |
2 - 450 |
| Mass |
kg |
680 |
930 |
1550 |
2150 |
| Displacement
/ Revolution |
cm3
/revolution |
350 |
505 |
750 |
1,015 |
|
|
|
|
|
|
| |